📢 Final call: FREE worldwide delivery ends on Mar. 31! No min purchase or code needed. 🛒 Shop now

Active

ESDALC6V1-5M6

5-line low capacitance Transil™ arrays for ESD protection

ECCN USEAR99
ECCN EUNEC
Package Size1.45 x 1.0
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameQFN-6L

The ESDALC6V1xxM6 are monolithic arrays designed to protect up to 4 or 5 lines against ESD transients.


The device is ideal for applications where both reduced print circuit board space and power absorption capability are required.

Key features
  • High ESD protection level
  • High integration
  • Suitable for high density boards
  • 4 unidirectional Transil diodes (ESDALC6V1M6)
  • 5 unidirectional Transil diodes (ESDALC6V1-5M6)
  • Breakdown voltage VBR= 6.1 V min
  • Low diode capacitance (12 pF typ at 0 V)
  • Low leakage current < 70 nA
  • Very small PCB area: 1.45 mm²
  • 500 microns pitch
  • Lead-free package
  • Complies with the following standards
    • IEC 61000-4-2
      • 15 kV (air discharge)
      • 8 kV (contact discharge)
    • MIL STD 883G- Method 3015-7: class3B
      • >8 kV (human body model)
In stock
Quantity $ per unit Savings
1-9$0.530%
10-99$0.4515%
100-200$0.3142%
Contact sales
$0.53
$0.53
ECCN USEAR99
ECCN EUNEC
Package Size1.45 x 1.0
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameQFN-6L

The ESDALC6V1xxM6 are monolithic arrays designed to protect up to 4 or 5 lines against ESD transients.


The device is ideal for applications where both reduced print circuit board space and power absorption capability are required.

Key features
  • High ESD protection level
  • High integration
  • Suitable for high density boards
  • 4 unidirectional Transil diodes (ESDALC6V1M6)
  • 5 unidirectional Transil diodes (ESDALC6V1-5M6)
  • Breakdown voltage VBR= 6.1 V min
  • Low diode capacitance (12 pF typ at 0 V)
  • Low leakage current < 70 nA
  • Very small PCB area: 1.45 mm²
  • 500 microns pitch
  • Lead-free package
  • Complies with the following standards
    • IEC 61000-4-2
      • 15 kV (air discharge)
      • 8 kV (contact discharge)
    • MIL STD 883G- Method 3015-7: class3B
      • >8 kV (human body model)