TCPP01-M12

TCPP01-M12

ECMF4-40A100N10

ECMF4-40A100N10

Active

ESDALC6V1M3

DUAL LOW CAPACITANCE TRANSIL ARRAY FOR ESD PROTECTION

ECCN USEAR99
ECCN EUNEC
Package Size1 x 0.6 x 0.45
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameSOT883

The ESDALC6V1M3 is a monolithic array designed to protect 1 line or 2 lines against ESD transients.


The device is ideal for applications where both reduced line capacitance and board space saving are required.

Key features
  • 2 unidirectional, low capacitance Transil diodes
  • Better than IEC 61000-4-2 standard (ESD protection: 11 kV contact discharge)
  • Breakdown voltage VBR= 6.1 V min
  • Low diode capacitance (11 pF typ at 0 V)
  • Low leakage current < 0.5 μA
  • Very small PCB area: 0.6 mm2
  • RoHS compliant
  • Benefits
    • High ESD protection level
    • High integration
    • Suitable for high density boards
  • Complies with the following standards
    • IEC61000-4-2 level 4:
      • 15 kV (air discharge)
      • 8 kV (contact discharge)
    • MIL STD 883G-Method 3015-7: class 3B:
      • HBM (human body model)
In stock
Quantity $ per unit Savings
1-9$0.410%
10-99$0.3028%
100-500$0.1759%
Contact sales
$0.41
$0.41
ECCN USEAR99
ECCN EUNEC
Package Size1 x 0.6 x 0.45
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameSOT883

The ESDALC6V1M3 is a monolithic array designed to protect 1 line or 2 lines against ESD transients.


The device is ideal for applications where both reduced line capacitance and board space saving are required.

Key features
  • 2 unidirectional, low capacitance Transil diodes
  • Better than IEC 61000-4-2 standard (ESD protection: 11 kV contact discharge)
  • Breakdown voltage VBR= 6.1 V min
  • Low diode capacitance (11 pF typ at 0 V)
  • Low leakage current < 0.5 μA
  • Very small PCB area: 0.6 mm2
  • RoHS compliant
  • Benefits
    • High ESD protection level
    • High integration
    • Suitable for high density boards
  • Complies with the following standards
    • IEC61000-4-2 level 4:
      • 15 kV (air discharge)
      • 8 kV (contact discharge)
    • MIL STD 883G-Method 3015-7: class 3B:
      • HBM (human body model)