Automotive dual-line TVS in SOT323-3L for CAN bus (24 V system)

Target ApplicationCAN
Operating Temp Max Celsius175.0
ECCN USEAR99
ECCN EUNEC
Package Size1.8 x 1.15 x 0.8
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeAutomotive
Package NameSOT323

These dual-line CAN transceiver protection devices (TVS) protect both CAN H and CAN L signals of automotive CAN PHY against ISO 7637-3 transients and ESD (electrostatic discharge).ESDCAN series complies with all the physical layer constraints (jump start, reverse polarity, …) without compromising...
Read More

Key features
  • AEC-Q101 qualified
  • Dual-line ESD and EOS protection
  • Breakdown voltage, VBR:
    • ESDCAN02-2BWY: 28.5 V
    • ESDCAN03-2BWY: 26.5 V
    • ESDCAN04-2BWY: 27.5 V
    • ESDCAN05-2BWY: 39 V
    • ESDCAN06-2BWY: 38 V
  • Max pulse power up to 170 W (8/20 μs)
  • Low clamping factor VCL / VBR
  • ECOPACK2 ROHS compliant component
  • UL94, V0
  • J-STD-020 MSL level 1
  • IPC7531 footprint and JEDEC registered package
  • ISO 16750-2 (Jump start and reversed battery tests)
  • IEC 61000-4-4 (EFT)
    • 4 kV
  • ISO 10605 C = 150 pF, R = 330 Ω, exceeds level 4:
    • ±30 kV (contact and air discharge)
  • ISO 10605 C = 330 pF, R = 2 kΩ exceeds level 4:
    • ±30 kV (contact and air discharge)
  • ISO 10605 C = 330 pF, R = 330 Ω exceeds level 4:
    • ±30 kV (contact and air discharge)
  • ISO 7637-3:
    • Pulse 3a: -150 V
    • Pulse 3b: +150 V
    • Pulse 2a: +/- 85 V
In stock
Quantity $ per unit Savings
1-9$0.391%
10-99$0.2926%
100-500$0.1367%
Contact sales
$0.39
$0.39
or
Target ApplicationCAN
Operating Temp Max Celsius175.0
ECCN USEAR99
ECCN EUNEC
Package Size1.8 x 1.15 x 0.8
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeAutomotive
Package NameSOT323

These dual-line CAN transceiver protection devices (TVS) protect both CAN H and CAN L signals of automotive CAN PHY against ISO 7637-3 transients and ESD (electrostatic discharge).ESDCAN series complies with all the physical layer constraints (jump start, reverse polarity, …) without compromising...
Read More

Key features
  • AEC-Q101 qualified
  • Dual-line ESD and EOS protection
  • Breakdown voltage, VBR:
    • ESDCAN02-2BWY: 28.5 V
    • ESDCAN03-2BWY: 26.5 V
    • ESDCAN04-2BWY: 27.5 V
    • ESDCAN05-2BWY: 39 V
    • ESDCAN06-2BWY: 38 V
  • Max pulse power up to 170 W (8/20 μs)
  • Low clamping factor VCL / VBR
  • ECOPACK2 ROHS compliant component
  • UL94, V0
  • J-STD-020 MSL level 1
  • IPC7531 footprint and JEDEC registered package
  • ISO 16750-2 (Jump start and reversed battery tests)
  • IEC 61000-4-4 (EFT)
    • 4 kV
  • ISO 10605 C = 150 pF, R = 330 Ω, exceeds level 4:
    • ±30 kV (contact and air discharge)
  • ISO 10605 C = 330 pF, R = 2 kΩ exceeds level 4:
    • ±30 kV (contact and air discharge)
  • ISO 10605 C = 330 pF, R = 330 Ω exceeds level 4:
    • ±30 kV (contact and air discharge)
  • ISO 7637-3:
    • Pulse 3a: -150 V
    • Pulse 3b: +150 V
    • Pulse 2a: +/- 85 V