Active

OCVPB21-13F6

ESD, Overvoltage and Overcurrent protection with charging orientation direction detection

Operating Temp Min Celsius-30.0
Operating Temp Max Celsius65.0
ECCN USEAR99
ECCN EUNEC
Package Size1.32 x 2.1
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameCSP P 0.4 mm

The OCVPB21-13F6 is an integrated ESD, overvoltage and overcurrent protection with an integrated input rectification bridge to give flexibility for wearable and IoT customers to manage properly any kind of USB charging conditions with or without USB cable inversion.Thanks to state of the art high...
Read More

Key features
  • USB interface protection between cable and charging circuit during battery charging with:
    • Exceeds ESD IEC 61000-4-2 level 4 protection on cable side: ±15 kV contact on bridge inputs, ±12 kV contact on USB data-lines inputs
    • Detection of the polarity of the charging cable with rerouting in case of cable inversion thanks to 13 V input rectification bridge
    • Overvoltage protection (OVP) up to ± 13 V
    • Over current protection (OCP) externally adjustable from 100 mA to 500 mA
    • Controlled inrush current
    • Over temperature protection
    • Under-voltage lockout
    • 5 V USB 2.0 data lines protection and multiplexer for data line polarity correction (RON = 6 Ω typical)
    • FLAG output signal (open-drain) available to inform thermal shutdown or overvoltage or overcurrent or uncompleted start-up phase
    • Proposed in 400µm pitch WLCSP package 13 bumps
    • Operating temperature from -30°C to 65°C
In stock
Quantity $ per unit Savings
1-9$1.590%
10-50$1.1428%
Contact sales
$1.59
$1.59
Operating Temp Min Celsius-30.0
Operating Temp Max Celsius65.0
ECCN USEAR99
ECCN EUNEC
Package Size1.32 x 2.1
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameCSP P 0.4 mm

The OCVPB21-13F6 is an integrated ESD, overvoltage and overcurrent protection with an integrated input rectification bridge to give flexibility for wearable and IoT customers to manage properly any kind of USB charging conditions with or without USB cable inversion.Thanks to state of the art high...
Read More

Key features
  • USB interface protection between cable and charging circuit during battery charging with:
    • Exceeds ESD IEC 61000-4-2 level 4 protection on cable side: ±15 kV contact on bridge inputs, ±12 kV contact on USB data-lines inputs
    • Detection of the polarity of the charging cable with rerouting in case of cable inversion thanks to 13 V input rectification bridge
    • Overvoltage protection (OVP) up to ± 13 V
    • Over current protection (OCP) externally adjustable from 100 mA to 500 mA
    • Controlled inrush current
    • Over temperature protection
    • Under-voltage lockout
    • 5 V USB 2.0 data lines protection and multiplexer for data line polarity correction (RON = 6 Ω typical)
    • FLAG output signal (open-drain) available to inform thermal shutdown or overvoltage or overcurrent or uncompleted start-up phase
    • Proposed in 400µm pitch WLCSP package 13 bumps
    • Operating temperature from -30°C to 65°C