Active

STEVAL-IPFC02V1

2 kW two-channel interleaved PFC reference design based on the STNRGPF02 digital controller

Operating RangeIndustrial
Core ProductSTNRGPF02, STGW20H65FB, STPSC12065D
Input Voltage Min Volt90.0
Input Voltage Max Volt265.0
ECCN USEAR99
ECCN EUNEC
Packing TypeNot Applicable
RoHs compliantEcopack2
GradeIndustrial
Package NameCARD

The STEVAL-IPFC02V1 2 kW interleaved PFC reference design features the performance of analog cycle-by-cycle current regulation and the flexibility of digital control to generate sinusoidal supplies with very high power factor and very low harmonic distortion.Digital power control is based on...
Read More

Key features
  • Input voltage range: 90 to 265 VAC
  • Line frequency range: 47 to 63 Hz
  • Maximum output power: 2 kW at 230 V
  • Inrush current limiter
  • Output voltage: 400 V
  • Power factor: > 0.98 at 20% load
  • Total harmonic distortion: <5% at 20% load
  • Mixed-signal average current mode control, CCM fixed frequency operation
  • Switching frequency (fsw): 60 kHz
  • Cycle-by-cycle regulation (analog current control loop)
  • Input voltage and load feed-forwards
  • Phase shedding
  • Current balance
  • Burst-mode operation
  • Overvoltage protection
  • Overcurrent protection
  • Thermal protection
  • Status indicator LEDs
  • Cooling function
In stock
Quantity $ per unit Savings
1$399.840%
Contact sales
$399.84
$399.84
Operating RangeIndustrial
Core ProductSTNRGPF02, STGW20H65FB, STPSC12065D
Input Voltage Min Volt90.0
Input Voltage Max Volt265.0
ECCN USEAR99
ECCN EUNEC
Packing TypeNot Applicable
RoHs compliantEcopack2
GradeIndustrial
Package NameCARD

The STEVAL-IPFC02V1 2 kW interleaved PFC reference design features the performance of analog cycle-by-cycle current regulation and the flexibility of digital control to generate sinusoidal supplies with very high power factor and very low harmonic distortion.Digital power control is based on...
Read More

Key features
  • Input voltage range: 90 to 265 VAC
  • Line frequency range: 47 to 63 Hz
  • Maximum output power: 2 kW at 230 V
  • Inrush current limiter
  • Output voltage: 400 V
  • Power factor: > 0.98 at 20% load
  • Total harmonic distortion: <5% at 20% load
  • Mixed-signal average current mode control, CCM fixed frequency operation
  • Switching frequency (fsw): 60 kHz
  • Cycle-by-cycle regulation (analog current control loop)
  • Input voltage and load feed-forwards
  • Phase shedding
  • Current balance
  • Burst-mode operation
  • Overvoltage protection
  • Overcurrent protection
  • Thermal protection
  • Status indicator LEDs
  • Cooling function