STIEC45-26AS Active

Transil (TVS) for IEC 61000-4-5 compliance
Quantity $ per Unit Savings
1 - 9$1.910%
10 - 99$1.6215%
100 - 249$1.2634%
250 - 499$1.2336%
500$1.0744%
Contact Sales
In stock:
$1.91
Parameter NameParameter Value
Operating Temp Min Celsius-55.0
Operating Temp Max Celsius150.0
ECCN USEAR99
ECCN EUNEC
Packing TypeTape And Reel
ROHS Compliance GradeEcopack2
GradeIndustrial
Package NameSMC
Key features
  • Peak pulse current: 500 A (1.2/50 μs, 8/20 μs)
  • Stand-off voltage range: from 24 V to 33 V
  • Unidirectional types: STIEC45-xxAS
    • Reverse: Clamping starts at
      VBR
    • Forward: Clamping starts around 0.6
      V
  • Bidirectional types: STIEC45-xxACS
    • Clamping starts at VBR
      on both directions
  • Low leakage current
    • 0.2 μA at 25 °C
    • 1
      μA at 85 °C
  • Operating Tj max: 150 °C
  • High peak current capability at Tj max: 410 A 8/20 μs
  • JEDEC registered package outline
  • RoHS2 compliant