📢 $9.99 flat rate shipping in EMEA countries! Ends April 30th - Don't Miss Out!. 🛒 Shop now

IPS160HFTR

IPS160HFTR

Active

IPS160HF

Single channel high-side switches

Operating Temp Min Celsius-40.0
Operating Temp Max Celsius150.0
ECCN USEAR99
ECCN EUNEC
Packing TypeTube
RoHs compliantEcopack1
GradeIndustrial
Package NamePowerSSO 12

The IPS160HF (Iout < 2.5 A) and IPS161HF (Iout < 0.7 A) are monolithic devices which can drive capacitive, resistive or inductive loads with one side connected to ground.The 60 V operating range and Ron = 60 mΩ, combined with the extended diagnostic (Open Load, Over Load, Overtemperature)...
Read More

Key features
  • 8 V to 60 V operating voltage range
  • Minimum output current limitation: 0.7 A (IPS161HF) or 2.5 A (IPS160HF)
  • Short propagation delay at start-up (≤ 60 μs)
  • Fast demagnetization of inductive load
  • Non-dissipative short-circuit protection (cut-off)
  • Programmable cut-off delay time using external capacitor
  • Ground disconnection protection
  • VCC disconnection protection
  • Thermal shutdown protection
  • Undervoltage lock-out
  • Diagnostic signalization for: open load in off-state, cut-off and junction thermal shutdown
  • Designed to meet IEC 61131-2
  • PowerSSO12 package
Out of Stock
Quantity $ per unit Savings
1-9$4.140%
10-24$3.7110%
25-99$3.5115%
100-249$2.9828%
250-499$2.8332%
500$2.5638%
Contact sales
$4.14
Operating Temp Min Celsius-40.0
Operating Temp Max Celsius150.0
ECCN USEAR99
ECCN EUNEC
Packing TypeTube
RoHs compliantEcopack1
GradeIndustrial
Package NamePowerSSO 12

The IPS160HF (Iout < 2.5 A) and IPS161HF (Iout < 0.7 A) are monolithic devices which can drive capacitive, resistive or inductive loads with one side connected to ground.The 60 V operating range and Ron = 60 mΩ, combined with the extended diagnostic (Open Load, Over Load, Overtemperature)...
Read More

Key features
  • 8 V to 60 V operating voltage range
  • Minimum output current limitation: 0.7 A (IPS161HF) or 2.5 A (IPS160HF)
  • Short propagation delay at start-up (≤ 60 μs)
  • Fast demagnetization of inductive load
  • Non-dissipative short-circuit protection (cut-off)
  • Programmable cut-off delay time using external capacitor
  • Ground disconnection protection
  • VCC disconnection protection
  • Thermal shutdown protection
  • Undervoltage lock-out
  • Diagnostic signalization for: open load in off-state, cut-off and junction thermal shutdown
  • Designed to meet IEC 61131-2
  • PowerSSO12 package
Associated products