Active

CBTVS2A16-1F3

TVS clamping array, ESD suppressor

Operating RangeCommercial
Operating Temp Min Celsius-30.0
Operating Temp Max Celsius85.0
ECCN USEAR99
ECCN EUNEC
Package Size0.77 x 0.77 x 0.50
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameCSP P 0.4 mm

The CBTVS2A16-1F3 is a single line diode TVS integrating a fuse designed specifically for the protection of integrated circuits in portable equipment and miniaturized electronic devices subject to ESD, OVP and OCP.

Key features
  • Transient voltage suppressor (TVS)
  • Non-resettable over current protection (OCP)
  • Electrostatic discharge protection
  • Electrical overstressed protection (OVP)
  • Unidirectional device
  • Low clamping factor VCL / VBR
  • Fast response time
  • Very thin package: 0.5 mm
  • Complies with the following standards:
    • IEC 61000-4-2 level 4:
      • ±15 kV (air discharge)
      • ±8 kV (contact discharge)
Out of Stock
Quantity $ per unit Savings
1-9$0.399%
10-99$0.2836%
100-500$0.1467%
Contact sales
Special Price $0.39 Regular Price $0.43
Operating RangeCommercial
Operating Temp Min Celsius-30.0
Operating Temp Max Celsius85.0
ECCN USEAR99
ECCN EUNEC
Package Size0.77 x 0.77 x 0.50
Packing TypeTape And Reel
RoHs compliantEcopack2
GradeIndustrial
Package NameCSP P 0.4 mm

The CBTVS2A16-1F3 is a single line diode TVS integrating a fuse designed specifically for the protection of integrated circuits in portable equipment and miniaturized electronic devices subject to ESD, OVP and OCP.

Key features
  • Transient voltage suppressor (TVS)
  • Non-resettable over current protection (OCP)
  • Electrostatic discharge protection
  • Electrical overstressed protection (OVP)
  • Unidirectional device
  • Low clamping factor VCL / VBR
  • Fast response time
  • Very thin package: 0.5 mm
  • Complies with the following standards:
    • IEC 61000-4-2 level 4:
      • ±15 kV (air discharge)
      • ±8 kV (contact discharge)