Active

EV-VNQ9080AJ

VNQ9080AJ evaluation board

Core ProductVNQ9080AJ
ECCN USEAR99
ECCN EUNEC
Packing TypeNot Applicable
RoHs compliantNot compliant
GradeIndustrial
Package NameCARD

The EV-VNQ9080AJ board provides an easy way to connect VNQ9080AJ into existing system.

Key features
  • Extreme low voltage operation for deep cold cranking applications (compliant with LV124, revision 2013)
  • General
    • Quad channel smart high-side driver with current sense analog feedback
    • Very low standby current
    • Compatible with 3 V and 5 V CMOS outputs
  • CurrentSense diagnostic functions
    • Multiplexed analog feedback of: load current with high precision proportional current mirror
    • Overload and short to ground (power limitation) indication
    • Thermal shutdown indication
    • Off-state open-load detection (with external pull-up)
    • Output short to VCC detection
    • Sense enable/disable
  • Protections
    • Undervoltage shutdown
    • Overvoltage clamp
    • Load current limitation
    • Self limiting of fast thermal transients
    • Configurable latch-off on overtemperature or power limitation with dedicated fault reset pin
    • Loss of ground and loss of VCC
    • Reverse battery with external components
    • Electrostatic discharge protection
In stock
Quantity $ per unit Savings
1$34.300%
Contact sales
$34.30
$34.30
Core ProductVNQ9080AJ
ECCN USEAR99
ECCN EUNEC
Packing TypeNot Applicable
RoHs compliantNot compliant
GradeIndustrial
Package NameCARD

The EV-VNQ9080AJ board provides an easy way to connect VNQ9080AJ into existing system.

Key features
  • Extreme low voltage operation for deep cold cranking applications (compliant with LV124, revision 2013)
  • General
    • Quad channel smart high-side driver with current sense analog feedback
    • Very low standby current
    • Compatible with 3 V and 5 V CMOS outputs
  • CurrentSense diagnostic functions
    • Multiplexed analog feedback of: load current with high precision proportional current mirror
    • Overload and short to ground (power limitation) indication
    • Thermal shutdown indication
    • Off-state open-load detection (with external pull-up)
    • Output short to VCC detection
    • Sense enable/disable
  • Protections
    • Undervoltage shutdown
    • Overvoltage clamp
    • Load current limitation
    • Self limiting of fast thermal transients
    • Configurable latch-off on overtemperature or power limitation with dedicated fault reset pin
    • Loss of ground and loss of VCC
    • Reverse battery with external components
    • Electrostatic discharge protection